QMI Aseptic Sampling System (7 Port)

Application: Sampling a low-viscous product such as water, milk or juice

qmi-aseptic-sampler

QMI 7-Port Aseptic Septum - Black
Can Only Be Used With
7 Port Stainless Fittings
Part # 110011 (formerly PN 7027)

qmi-aseptic-sampler-silicone

QMI 7-Port Septum - Silicone High Temperature
This Port Should Be Used For High
Temperature Applications (Up To 280ºF)
Can Only Be Used With 7 Port
Stainless Fittings
Part # 110021 (formerly PN 7027S)

qmi-probe-septum

QMI Probe Septum
It is designed with one large needle channel
in the middle of the Septum.
Part # 110031 (formerly PN 7027P)
Learn more...

 

7 Port Stainless Fittings Available

qmi-tri-clamp-elbows

QMI 7-Port Tri-Clamp Elbows, with Nut, Stainless Steel
(Standard Long Radius)

1 ½” diameter: Part #213023 (formerly PN 2176 (304))
2” diameter: Part #213027 (formerly PN 2184 (304))
2 ½” diameter: Part #213031 (formerly PN 2188 (304))
3” diameter: Part #213035 (formerly PN 2192 (304))

* Available in 304 or 316L Stainless Steel.

qmi-weld-elbows

QMI Weld Elbows, with Nut, Stainless Steel
(Standard Long Radius)

1 ½” diameter: Part #213073 (formerly PN 2200 (304))
2” diameter:Part #213077 (formerly PN 2218 (304))
2 ½” diameter:Part #213081 (formerly PN 2222 (304))
3” diameter: Part #213085 (formerly PN 2226 (304))

* Available in 304 or 316L Stainless Steel.

juice

QMI 7-Port Tank Fitting: Non-Insulated, with Nut, Stainless Steel
Click Here For Installation Drawing
Part #212111 (formerly PN 2234 (304))

Part #212113 (formerly PN 2234 (316L))

eggs

QMI Insulated Tank Fitting, with Nut, Stainless Steel
1.875”depth: Part #212121 (formerly PN 2236-2" (304))
4”depth: Part #212125 (formerly PN 2236-4" (304))
5 ½”diameter (4” depth): Part #212131 (formerly PN 2238-4"x5" (304))
* Also available in 316L Stainless Steel.
Click Here For Installation Drawing

water

QMI 7-Port End Cap, Tri-Clamp, with Nut, Stainless Steel 316L
1 ½”: Part #211125 (formerly PN 2400 (316L))
2”: Part # 211129 (formerly PN 2410 (316L))
2 ½”: Part # 211133 (formerly PN 2420 (316L))

qmi-safe-septum-fittings-male

QMI 7-Port Male Threaded Fitting,  with Knurled Nut, Stainless Steel 316L
M-26x1.5 Threads Part # 217221 (formerly PN  2000M-26x1.5 (316L))

M-1x112TPi Threads Part # 217243 (formerly PN  2000M-1x12TPi (316L))

qmi-safe-septum-fittings-female

QMI 7-Port Female Threaded Fitting, 19mm Threads, with Knurled Nut, Stainless Steel 316L
Part #217101 (formerly PN 2000F (316L))


qmi-needle

Needle, 1.5", industrial, non-medical
16 gauge: Part #113316 (formerly PN 2380)
18 gauge: Part #113318 (formerly PN 2382)
20 gauge: Part #113320 (formerly PN 2383)
22 gauge: Part #113322 (formerly PN 2384)
23 gauge: Part #113323 (formerly PN 2385)

qmi-syringe

QMI Syringe
60cc: Part #113120 (formerly PN 2374)
140cc: Part #113150 (formerly PN 2376)



QMI Sampling Bag

QMI Composite Sampling Assemblies
sealed with bag, tubing and 18 gauge needle


Part # 111450 (formerly PN 2388): Sampling Assembly with 250 milliliter bag (250ml)
Note: this part does NOT work with a peristaltic pump.

Part # 111730 (formerly PN 2392): Sampling Assembly with 2 Liter Bag (2L)
Note: this part does NOT work with a peristaltic pump.

Part # 111750 (formerly PN 2392P-2.0mmID): Sampling Assembly with 2 Liter Bag (2L)
for Peristaltic Pump with 2.0mm inner diameter tubing
(such as certain Piper Systems Peristaltic Pumps)

Part # 111770 (formerly PN 2392P-3.2mmID): Sampling Assembly with 2 Liter Bag (2L)
for Peristaltic Pump with 3.2mm inner diameter tubing
(such as certain Watson-Marlow Peristaltic Pumps)

Part # 111930 (formerly PN 2394): Sampling Assembly with 5 Liter Bag (5L)
Note: this part does NOT work with a peristaltic pump.

Pump and Fridge

Above photo shows the QMI Sampling Assembly, PN 2392P-3.2mmID, with a special tubing segment for use with peristaltic pump rollers.


















qmi-tamper-evident-device

QMI Tamper Evident Device (TED)
With Security Seal

TED (Set of 2 pieces)Part #310021 (formerly PN 2360)
Security Seal, numbered (not sequentially) Part #310020 (formerly PN 2365)

qmi-sampling-kit

QMI Sampling Kit
Part #: 1079
Contents: 7-Port Sampling Kit - Septum, 7 needles (18g),
7 Syringes (60cc), alcohol wipes,
dust cover

Part#114018 (formerly PN 1079)

qmi-7-port-sampling-wrench

QMI 7 Port Sampling Wrench
Part #310011 (formerly PN 2350)








qmi-7-port-dust-covers

QMI 7 Port Dust Cover
Part #310121 (formerly PN 1007)
The QMI Dust Cover fits over the stainless nut
to protect the Aseptic Sampler from dust
and moisture. Each stainless fitting sold
is shipped with one Dust Cover.

qmi-stainless-7port-replacement-nut

QMI Stainless 7 Port Replacement Nuts

Please Note: Each Stainless Fitting Ordered
Is Equipped With A Stainless Nut.

7-Port Replacement Nut, narrow (low profile): Part #219021 (formerly PN 2553) [use with Part #211123 (formerly PN 2420) and Part #211125 (formerly PN 2400)]


7-Port Replacement Nut, regular: Part # 219023 (formerly PN 2555)  [use for all 7-Port fittings except Part #211123 (formerly PN 2420) and Part #211125 (formerly PN 2400)]

qmi-flow-clamp

QMI Flow Clamp
Flow Control Clamp [use for Sampling Bags PN 2392 and Part #111930]: Part #112010 (formerly PN 2398)


get_a_quote

place_order

news_archive


youtube